SINGLE-POLE TANDEM BREAKER
Breakers trip both thermally/magnetically
SWD switch rating on 15/20 amp breakers
Quick make-quick break mechanism
Tandem circuit breakers
Single-pole 1-1" space required
Clamshell packing
HOMT1515 15A SGL POLE BREAKER
SIZE:15/15 Amp
|
This item can NOT be shipped to these states CA
TANDEM BREAKER Type: BD duplex Provides 2 single-pole circuits 1" space required 120/240V AC - 10,000 AIC BD1515 15A TANDEM BREAKER SIZE:15/15 Amp |
This item can NOT be shipped to these states CA
TANDEM BREAKER Type: BD duplex Provides 2 single-pole circuits 1" space required 120/240V AC - 10,000 AIC BD2020 20/20A TANDEM BREAKER SIZE:20/20 Amp COLOR: |
SINGLE-POLE TANDEM BREAKER
Breakers trip both thermally/magnetically
SWD switch rating on 15/20 amp breakers
Quick make-quick break mechanism
Tandem circuit breakers
Single-pole 1-1" space required
Clamshell packing
HOMT2020 20A DBL POLE BREAKER
SIZE:20/20 Amp
COLOR:
|
Plug-type circuit breaker. For use with plug fuse panels.
Amp Rating=15
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
Homeline 100 amp double-pole circuit breaker for overload and short-circuit protection of an electrical system. Common-trip design with a thermal-magnetic tripping mechanism. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre
Interrupting Rating (AIR). CSA approved to only install in Canadian HomeLine loadcentres.
Amp Rating=100
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
This item can NOT be shipped to these states CA
TYPE BR 1" CIRCUIT BREAKERS 1" wide per pole - molded case - Type BR Primary function is to protect the wire from - overheating because of overload or fault - currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application BR120 20A SP WESTINGHS BREAKER SIZE:20 Amp - 1-Pole PACK TYPE:Bulk Pack |
Amp Rating=20
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
HOMELINE SINGLE-POLE BREAKER
Breakers trip both thermally/magnetically
SWD switch rating on 15/20 amp breakers
Quick make-quick break mechanism
Single-pole 1" space required
HOM150 50A SGL POLE BREAKER
SIZE:50 Amp
COLOR:
|
This item can NOT be shipped to these states CA
TYPE BR 1" CIRCUIT BREAKERS 1" wide per pole - molded case - Type BR Primary function is to protect the wire from - overheating because of overload or fault - currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application BR230 30A DP BR SERIES BREAKER SIZE:30 Amp - 2-Pole PACK TYPE:Bulk Pack |
ITE SIEMENS TANDEM BREAKER
Twin single-pole
120/240 volts
Interchangeable circuit breaker
Q1515 ITE SIEMENS BREAKER
SIZE:15/15 Amp
|
ITE SIEMENS TANDEM BREAKER
Twin single-pole
120/240 volts
Interchangeable circuit breaker
Q2020 ITE SIEMENS BREAKER
SIZE:20/20 Amp
COLOR:
|
This item can NOT be shipped to these states CA
TANDEM BREAKER Type: BD duplex Provides 2 single-pole circuits 1" space required 120/240V AC - 10,000 AIC BD3030 30/30 TANDEM BREAKER SIZE:30/30 Amp COLOR: |
Non-interchangeable trip. 120 volt AC; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sea
rs. UL Listed, HACR rated. 15 and 20 amp UL Listed for frequent switching applications, 120 volt AC fluorescent lighting. 1" per pole.
Amp Rating=20
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
| Ring Type |NEMA 3R Raintight For Outdoor Use | Includes 200 Amp Main Breaker And 8 Spaces For Additional Breakers (8 Single Pole Or 4 Double Pole) | Overhead Feed|120/240V
|
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL
Listed. HACR rated. 120/240 volt AC; 10,000 AIR. 1" per pole (2" total).
Amp Rating=30
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
HOMELINE DOUBLE-POLE BREAKER
Plug-on circuit breakers
Breakers trip thermally/magnetically
Quick make-quick break mechanism
2-pole - 2-1" spaces required
120/240V AC
UL listed
HOM270 70A DBL POLE BREAKER
SIZE:70 Amp
COLOR:
|
This item can NOT be shipped to these states CA
TYPE BR 1" CIRCUIT BREAKERS 1" wide per pole - molded case - Type BR Primary function is to protect the wire from - overheating because of overload or fault - currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application BR115 15A SP WESTHSE BREAKER SIZE:15 Amp - 1-Pole PACK TYPE:Bulk Pack |
SINGLE POLE FEDERAL PACIFIC BREAKER
Thin single-pole
Thin series single-pole breaker
Requires 1/2 of 1 space
Type UPIF for use in Federal Pacific -
load centers
UBIF020N FED PACIFIC BREAKER
SIZE:20 Amp
COLOR:
|
This item can NOT be shipped to these states CA
TYPE BR 1" CIRCUIT BREAKERS 1" wide per pole - molded case - Type BR Primary function is to protect the wire from - overheating because of overload or fault - currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application BR260 60A DP WESTHSE BREAKER SIZE:60 Amp - 2-Pole PACK TYPE:Bulk Pack |
Outdoor circuit breaker enclosure, 200 amp. NEMA type 3R for exterior use. Includes a QOM2200VH circuit breaker and a QOM22225NRB enclosure. UL Listed.
Amp Rating=200
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
Murray plug in circuit breakers are intended for use in Murray load centers or meter combinations. The single pole Murray breakers may be used in single or 3-phase load centers and are 120V rated. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required.
|
DOUBLE FEDERAL PACIFIC THICK BREAKER
Thick double pole replacement circuit breaker
For Federal Pacific electric type NA -
(thick) breakers
10,000 AIC - 2-pole
ETL Listed
UBIF250N FED PAC THICK BREAKER
SIZE:50 Amp
COLOR:
|
Murray space saving, plug in circuit breakers are intended for use in Murray load centers and meter combinations that are rated to accept type MH-T breakers. Check wiring diagram to confirm. To ensure the warranty on a Murray panel is not voided, the use of Murray breakers is required.
|
Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker.
CSA approved Canadian Square D QO loadcentre.
SINGLE POLE - 1 SPACE
Amp Rating=30
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per p
ole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth
. 120/240 volt; 10,000 AIR.
Amp Rating=50
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
SINGLE POLE & 2-POLE TANDEM BREAKERS
20/20 amp
2 circuits on 1 place
120/240 V AC
Circuit limiting
For load center with pan rail slots
5224381 for old style non-class CTL QO load-
centers built prior to 1967
QO-2020 20AMP DBL BREAKER
SIZE:20/20 Amp
For Earlier QO Load Centers-Non-Circuit Limiting
|
This item can NOT be shipped to these states CA
100 AMP MAIN BREAKER VALUE PACK 100A main breaker installed indoor load center Combination cover for flush or surface mounting 20 space - 20 single poles Includes (2) 20 Amp single pole breakers and - (1) 30 Amp 2-pole breaker BRP20B100V25 100A MAIN BREAKER |
Double-pole 3/4" plug-in branch circuit breaker that provides overload protection in QO load centers and enclosures. Visi-Trip indicator provides a visible cue that a circuit has been tripped. Accepts aluminum or copper conductors. Rated for 120/240Vac an
d at 10,000 Ampre Interrupting Rating (AIR). UL Listed, CSA Approved.
WITH VISI-TRIP INDICATOR
Amp Rating=40
This item cannot be shipped to APO/FPO addresses. Please accept our apologies
|
| These Space Saver Triplex Breakers Provide A Double Pole Common Trip Breaker For 120/240V Circuits And Two Single Poles For 120V Circuits | Triplex Require Two Panel Spaces | Hacr Rated
|
SINGLE POLE QO CIRCUIT BREAKER Single pole breakers with VISA-Trip indicator When breaker trips, the handle snaps to a mid- point position & red indicator identifies trip UL Listed - CSA Approved 120 / 240 Vac - 10,000 AIR Plug-on design - easy to install - wire - terminals UL listed for 2 branch wires (10-30A) Available clam shell pack or bulk bar coded QO115 15AMP SGL POLE BREAKER SIZE:15 Amp PACK TYPE:Bulk
|
This item can NOT be shipped to these states CA
TYPE BR 1" CIRCUIT BREAKERS 1" wide per pole - molded case - Type BR Primary function is to protect the wire from - overheating because of overload or fault - currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application BR220 20A DP WESTHSE BREAKER SIZE:20 Amp - 2-Pole PACK TYPE:Bulk Pack |
|
|
|
|
Copyright © 1999-2019 BuilderDepot, Inc. Site Designed and Maintained by Inline Internet Systems, Inc. |